Loft insulation

Loft insulation, specified for your roof

When a multifoil may suit, when mineral wool, rigid board or a combined build-up is better, and what a written specification should identify before anyone quotes.

Call 0800 772 3430

Storage loft lined with SF19 SuperFOIL multifoil, with boxes stacked by the gable window

The options

Four ways to insulate a roof space

OptionWhere it tends to suitWhat to keep in mind
Mineral wool at ceiling levelA standard cold loft used for storage, with room for depthThe usual low-cost route. Needs depth, and storage boards shouldn’t squash it. Keep the eaves clear
Rigid boardWhere depth is limited, or between and under raftersHigher resistance for its thickness. Moisture design still applies
Multifoil, such as SF19+Limited depth, usually as part of a designed build-upA vapour control layer, so its position matters. Not normally enough alone
A combined build-upRooms in the roof, and many roofs after foam removalMore than one layer, specified together, with the U-value calculated for the whole
Loft with both roof slopes lined with SF19 SuperFOIL multifoil behind timber battens, a roof window letting in daylight

Suitability

When SF19+ may not be the best choice

We’re happy to talk you out of it. These are general points, for a qualified person to confirm against your roof.

If this sounds like your loftWhy
A plain cold loft, used for storage, with accessible joistsMineral wool is the normal, low-cost route. A multifoil adds cost and detail for little reason.
Already adequately insulated, and needing only a top-upAdding more to a loft that’s already insulated generally makes much less difference, so an expensive layer is hard to justify.
Leaks, rot, condensation or blocked eavesFix the cause first. A vapour-closed layer can hide a moisture problem, or make it worse.
Already has foam or another vapour-closed layerA second vapour-closed layer without analysis could trap moisture.
You’re expecting thin insulation to match deep woolThe data doesn’t support that. One thin layer doesn’t reach the standard on a normal roof.
Near flues, or in an unusual or listed buildingThese need separate assessment, including of fire performance.
You need lender acceptanceWe found no lender criteria for SF19+ and don’t promise any.

Where it can be reasonable: limited headroom under rafters in a room in the roof where the certified system is specified, combined build-ups with mineral wool or rigid board, and roofs where foam has come out and a qualified person has approved a specification.

The specification

What it identifies

Every proposal rests on a written specification, approved by a named qualified person, before the quotation is finalised. It covers:

  • Roof or ceiling insulation position
  • Existing insulation
  • Membrane
  • Air spaces
  • Ventilation
  • Vapour control
  • Moisture risk
  • Junctions
  • Intended use of the space
  • U-value of the complete build-up, calculated for your roof

That’s also what we’d want you to ask any installer for. If they can’t say where the insulation goes, what’s happening with ventilation and what the whole roof achieves, you’re buying a product and not a solution. We don’t publish fitting instructions, because they only hold good for one roof.

Regulations

Building Control in plain English

Insulating a roof space on its own

If that’s the only work and it isn’t being done to comply with a requirement, it’s listed as not needing a building notice or application in England and Wales. The work must still meet the regulations.

As part of something bigger

Roof renovation, re-roofing or a loft conversion can be notifiable. So may insulation following foam removal, so we check for combined jobs.

England and Wales differ

Each has its own Approved Document L, and new editions apply from March 2027. Your specification states which it follows.

Ask at the survey whether your job needs Building Control and what paperwork you’ll receive, and get the answer in writing.

Pricing factors

What affects the price

Roof size and type

The area to be insulated, and how the roof is built.

Access

The hatch, boarding, and working space.

What comes out

Existing insulation or foam to remove first.

The specified build-up

The materials and layers your roof needs.

Finishing

Boarding, plasterboard and any electrical or ventilation work.

Fees

Scaffolding or Building Control fees, if the job needs them.

Keep reading

Related pages

Request an Insulation Assessment

Start with your name, postcode and how you’d like us to get in touch. Anything else is optional, and “not sure” is always fine.

We reply as soon as we can.

Call 0800 772 3430

About you

We use this to check whether we cover your area. We review every enquiry, even if you are further away.

How would you like us to contact you?
How we can reach you

We need a phone number or an email address, whichever suits you.

SuperFOIL insulation
What is the loft used for?
More detail, if you have it

All optional. Skip anything you like: we can ask when we talk. We treat your answers as a starting point until we have checked them.

What insulation is there now? (optional)
Any signs of condensation or damp? (optional)
Roughly how big is the house? (optional)
How do you get into the loft? (optional)
Do you own the property? (optional)
When are you hoping to go ahead? (optional)

Leave blank if not. Please don't include bank details or health information.

JPEG, PNG, WebP, HEIC or PDF. Up to 5 files, 8 MB each. Please cover any account numbers, and don't send anything showing bank or card details or ID. You can also skip this and send files later by email.

    Optional: would you also like occasional news and offers about Top Home Improvements services? Tick any you are happy with. Your enquiry is sent either way, and you can opt out at any time.

    We will use these details to reply to this enquiry. Read our privacy notice (opens in a new tab).